S.A.I.D.S.A

Installation Specification

S.A.I.D.S.A

Our Minimum Installation Specification we adhere to:

  • The control panel, radio antenna and transformer must be in a protected area.
  • Minimum signals i.e burglary and panic must be monitored separately.
  • All detection zones to use end-of-line resistors and must be correctly terminated.
  • All detectors must be screwed down. Glue on double-sided tape is not permitted.
  • The mains transformer must be minimum of 30VA. The cable from the transformer to the control panel must have a minimum core diameter of .5mm.
  • The standby battery must have a minimum capacity of 7.0 Amps per hour and be of the sealed type or have a minimum standby time of 6 hours for any part of the system.
  • A maximum of 2 (two) electronic detection devices may be connected on a circuit, except in zone doubling then 1 (one) electronic detector is permitted.
  • A maximum of 5 (five) magnetic contacts may be connected on a circuit except in zone doubling then 1 (one) magnetic contact per circuit.
  • All joints must be soldered and insulated or in a junction box.
  • The radio transmitter and antenna must be correctly mounted to manufacturers specification. The DC power cable from the control panel to the radio transmitter to the to have a minimum core of 0.5mm.
  • Where ceiling access is possible, the control panel, radio transmitter and antenna must be mounted at least 1.5 meters below the ceiling or in a location that does not leave the panel venerable to tampering. Control panels, radio, antennas and transformers may not be installed in the ceiling void. The control panel, radio and antenna mau not be mounted less than 1.5 meters from any external window ad must not be visible from the outside.
  • Detector lenses must be suitably fixed in such a way as to prohibit their east removal from the outside of the housing.
  • Cables to the Radio and antenna must be wired below the ceiling.
  • The control panel housing and electronic detection devices e.g PIR, glassbreak, ect must be tamper protected on a 24 hour zone in retail, commercial, industrial or high risk domestic installations. Wiring of electronic detectors may not use a common negative cable.
  • All cables that are venerable to corrosion and damage as well as external wiring must be suitably protected or placed in conduit.
  • All Zones must be multi-shot.
  • The control panel must have a minimum 128 event log.
  • Mechanical key switches, car batteries and shunt locks (cut out switches) are not permitted.
  • Commercial, Industrial, Retail and high risk domestic installations must have dual monitoring.
  • All equipment must be installed to manufacturers specifications.

Satisfaction Guaranteed

“In this world of poor customer service and unreliability, Joshua Morris are an amazing backing for a critical fail safe part of my life for more than 10 years ,a really excellent well run company. “

Alan Gross

Customer

“Chris, please relay my thanks to your team for the speedy resolution of the Electric Fence problem at my home in Linden. As usual I know I can always rely on you !”
Mike Francisco

Customer

Satisfied

As a licensed Security Installer, we know the value of speed and security

Protection is Our Business. Protection is our profession. Protection is the Key. Protective Services. Providing professional security in an insecure world.

VISIT US

159 Beyers Naude Drive, Northcliff, Johannesburg
2194

Call Us

(011) 888-4000

Call Now